BHU Digital Repository

Safety of subarachnoid block for elective cesarean delivery in women with major degree placenta previa

Show simple item record

dc.contributor.author Anzaku, SA
dc.date.accessioned 2024-05-28T13:10:01Z
dc.date.available 2024-05-28T13:10:01Z
dc.date.issued 2016
dc.identifier.citation Edem BE, Anzaku AS, Ngwan SD, Efu ME, Opita AJ. Safety of subarachnoid block for elective cesarean delivery in women with major degree placenta previa. J Med Trop 2016;18:68-72. en_US
dc.identifier.issn 2276-7096
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/1490
dc.description.abstract Background: Placenta previa is a serious complication of pregnancy, often causing antepartum hemorrhage with significant fetomaternal morbidity and mortality. The ideal anesthetic technique for cesarean section is controversial because of associated complications. The study aimed at ascertaining the safety of subarachnoid block among women with major degree placenta delivered by elective cesarean section. Materials and Methods: This was a prospective analysis of 11 parturients of the American Society of Anesthesiologists Class I/II with major degree placenta previa billed for elective cesarean section, who desired and consented for spinal anesthesia over a 32‑month period. Spinal anesthesia was induced with 10 mg heavy bupivacaine plus 0.5 mg morphine sulfate after a 2‑L infusion of normal saline. The surgeon incised the uterus only after 10 IU of intravenous oxytocin was given. Data collected included pre‑ and post‑operative packed cell volume (PCV), mean arterial pressure (MAP), pulse rate, peripheral oxygen saturation, estimated blood loss (EBL), and Apgar scores. The data were analyzed using SPSS version 21 for Windows® with statistical significance set at P < 0.05. Results: The mean preoperative PCV was 33.6 ± 3.5% and pulse rate was 99.3 ± 8.5/min while MAP was 97.9 ± 9.9 mmHg. Mean EBL was 918.2 ± 499.6 ml. Apgar scores at 1 and 5 min were 8.8 ± 1.2 and 10.00, respectively. There was no statistical significance between pre‑ and post‑operative parameters: Pulse rate 95.71 ± 14.07/min (P = 0.96), MAP 95.7 ± 12.13 (P = 0.70), and PCV 30.3 ± 3.9 (P = 0.32). Ten parturients (90.9%) had spinal hypotension. There was no maternal or fetal death. Conclusion: Subarachnoid block is safe in women undergoing cesarean delivery for major degree placenta previa, but anticipation for hypotension is important. en_US
dc.description.sponsorship Bassey E. Edem, Ajen S. Anzaku1, Stephen D. Ngwan2, Michael E. Efu, Ada J. Opita3 en_US
dc.language.iso en_US en_US
dc.publisher Journal of Medicine in the Tropics en_US
dc.relation.ispartofseries 18;2
dc.subject Cesarean section, placenta previa, spinal anesthesia en_US
dc.title Safety of subarachnoid block for elective cesarean delivery in women with major degree placenta previa en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search BHUDR


Advanced Search

Browse

My Account