BHU Digital Repository

PrimeStore MTM and OMNIgene Sputum for the Preservation of Sputum for Xpert MTB/RIF Testing in Nigeria.

Show simple item record

dc.contributor.author JOHN, S. Bimba
dc.contributor.author LOVETT, Lawson
dc.contributor.author KONSTANTINA, Kontogianni
dc.contributor.author THOMAS, Edwards
dc.contributor.author BASSEY, Emanna Ekpenyong
dc.contributor.author JAMES, Dodd
dc.contributor.author EMILY, R. Adams
dc.contributor.author DEREK, J. Sloan
dc.contributor.author JACOB, Creswell
dc.contributor.author JOSE, Dominguez
dc.contributor.author LUIS, E. Cuevas
dc.date.accessioned 2024-05-31T17:59:00Z
dc.date.available 2024-05-31T17:59:00Z
dc.date.issued 2019-12-04
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/1581
dc.description.abstract Xpert MTB/RIF (GX) for tuberculosis (TB) diagnosis is often located in reference laboratories, and sputum needs to be transported using a cold chain. Transport media to preserve sputum are available, but performance data under programmatic conditions are limited.Methods: Sputum samples were collected from patients with presumptive TB in Nigeria. One sputum was transported in a cold chain, tested immediately with GX and cultured. One sputum was swabbed and stored in PrimeStore-Molecular-Transport-Medium (Primestore), and the remainder was stored in OMNIGene-sputum (Omnigene), kept for seven days and tested with GX. Results: Of 248 patients, 63 were fresh-sputum culture-positive and 56 GX-positive (sensitivity 88.9%, 95% CI: 78.4–95.4%). Four of 185 culture-negative patients were GX-positive (specificity 97.8%, 94.6–99.4%). Omnigene GX and Primestore GX were positive in 56/62 (90.3%, 80.1–96.4%) and 49/62 (79.0%, 66.8–88.3%culture-positive, respectively, and 1/185 (99.5%, 97.0–100.0%) and 3/185 (98.4%, 95.3–99.7%) were culture-negative patients. 14 Human Immunodeficiency Virus (HIV)-infected and 44 HIV-uninfected patients were culture-positive. Omnigene and Primestore detected 12/14 (85.7%, 57.2–98.2%) and 5/14 (35.7%, 12.8–64.9%) HIV-infected and 41/44 (93.2%, 81.3–98.6%) HIV-uninfected culture-positive patients. Interpretation: Omnigene stored and fresh sputum samples had similar GX results. The GX results of Primestore-stored samples were similar to those found in the fresh sputum of non-HIV infected patients, but GX-positivity was lower in HIV-infected patients. This was likely due to the lower amount of bacilli collected by the swab and transferred to PrimeStore. en_US
dc.language.iso en en_US
dc.publisher JORNAL OF CLINICAL MEDICINE en_US
dc.subject Tuberculosis en_US
dc.subject Diagnosis en_US
dc.subject OMNIGene-sputum en_US
dc.subject PrimeStore en_US
dc.subject Xpert MTB/RIF en_US
dc.title PrimeStore MTM and OMNIgene Sputum for the Preservation of Sputum for Xpert MTB/RIF Testing in Nigeria. en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search BHUDR


Advanced Search

Browse

My Account